Canon imageFORMULA P-215 Replacing Consumable Parts (Feed Roller and Separation Pad)Manual
The feed rollers and separation pad inside the scanner are consumable parts and will wear with scanning. If either the feed roller or the separation pad or both are worn, documents may not feed correctly and paper jams may occur. When the total number of pages of documents fed in the scanner exceeds the following quantity, a message appears when the scanner is connected to the computer. In such cases, you must replace the part indicated in the message.
Feed Roller and Separation Pad need to replaced after 100,000 sheets . see price detail and buy here
Furthermore, the counter in the scanner that records the number of pages fed also needs to be reset when you replace the rollers
Hint :
This message only serves as a rough guide for when to replace the feed roller and separation pad. They may wear out sooner if, for example, a lot of pages with rough surfaces are scanned.
IMPORTANT :
This section describes the procedure to use when the Auto Start switch on the rear panel of the scanner is set to the “OFF” position. If the Auto Start switch is set to the “ON” position (when you only use CaptureOnTouch Lite and have not installed CaptureOnTouch and the scanner driver on your computer), you cannot reset the counter using this procedure. In this case, you can reset the counter from CaptureOnTouch Lite. For details, see p. 41 (Windows) or see p. 72 (Mac OS X).
Feed Roller and Separation Pad need to replaced after 100,000 sheets . see price detail and buy here
Furthermore, the counter in the scanner that records the number of pages fed also needs to be reset when you replace the rollers
Hint :
This message only serves as a rough guide for when to replace the feed roller and separation pad. They may wear out sooner if, for example, a lot of pages with rough surfaces are scanned.
Replacing Paper Feed Roller Canon imageFORMULA P-215
Replacing the Separation Pad Canon imageFORMULA P-215
Use the following procedure to replace the separation pad.Resetting the Counters Value Canon imageFORMULA P-215
Make sure to reset the scanner’s internal counters using the following procedure whenever you replace the feed roller or separation pad.IMPORTANT :
This section describes the procedure to use when the Auto Start switch on the rear panel of the scanner is set to the “OFF” position. If the Auto Start switch is set to the “ON” position (when you only use CaptureOnTouch Lite and have not installed CaptureOnTouch and the scanner driver on your computer), you cannot reset the counter using this procedure. In this case, you can reset the counter from CaptureOnTouch Lite. For details, see p. 41 (Windows) or see p. 72 (Mac OS X).